If there are any issues for payments to Russia from your country you can make transfer to our Kazakhstan Partner

Detection and locating, measuring equipment
Water leak detectors, cable and pipe locators

Cable and pipe locator Success AG-317G

Features:

  • Detection of optic fiber cables on depth up to 10 meters.
  • Location of underground utilities at distance up to 5 kilometers.
  • Cable & pipe tracing with measurement of burial depth and current rate.
  • Portable transmitter with up to 60W of power to locate almost any pipe or cable below ground surface.
  • GIS mapping of located cables & pipes with supplied software and built-in GPS module.
  • Electromagnetic PVC pipe location mode.

Overview

Brief description:

  • Three modes of operation : "ROUTE”, "GRAPHIC”, “FRIEND-OR-FOE”.
  • Three inbuilt sensors make omnidirectional antenna showing a direction of a cable or a metal pipeline on LCD display.
  • Inbuilt sensor for digital measurement of the depth and current.
  • Measured depth is 10 m.
  • Passive frequency: Power, Radio, BB.
  • Active frequency: 512/1024/8192/32768 Hz.
  • Sensitivity : 100μA.
  • Large LCD display with high resolution and adjustable backlight brightness.
  • Transmitter – 60W.
  • Cast body, the case is sealed along the entire length to the connectors.
  • Warranty: 1 year.

Application:

  • Detection of cables and any metal pipelines underground up to 10 m.
  • Direct digital measurement of the depth up to 10 m.
  • Indication of the deviation from the utility axis in the mode “ROUTE”.
  • Direct digital measurement of the current.
  • Survey the ground before the excavation works.
  • Tracing of metal utilities at distance up to 5 km.

Specifications

Receiver AP-019.3 Specifications

Parameter Value
Quasi-resonant frequencies of the filter 50(60)/ 100(120)/ 512/ 1024/ 8192 / 32768 Hz
Quasiresonant filter quality factor (Q) Not less than 100
Frequency range "Broad band" 0,04 to 8 kHz
Frequency range "Radio" 8 to 40 kHz
The maximum gain of the electric path >100 dB
Number of built-in sensors 4
Connected external sensors CI-105, HP-117, DODK-117, DKI-117 (made by «TECHNO-AC»)
Sensitivity control Auto - for 2D display «Route». Semi-automatic or manual (optional) - for the «Graphics». Automatic or manual (optional) - for the «2F» mode.
Determination the burial depth of the route Automatically in the mode Route 0 to 9,99 m
The accuracy of determining of the depth ±5%
Measurement of the current of the signal received Automatically in the mode Route 0.001 to 9,99 A
Accuracy of the measurement of the current of the signal received ±5%
Support of energy saving (intermittent) modes of the route locating generators At combined work with the route locating generators made by "TECHNO-AC" ("Pulse" mode)
Visual indication LCD display, 320x240 pix., LED lighting
Induced parameters

- parameters of setting and control;

- 2D visualization of the route location relative to the device;

- graphics of the signal level from sensors;

- route burial depth;

- signal current.

Audio indication Built-in transmitter - synthesized sound HM- sound indication of buttons pressing
Power supply source 4 to 7 V (4 elements of C type)
Time of continuous work from the one complete of the alkaline batteries Not less than 20 hours
Temperature range for storage / operation -30 to 60°С / -20 to 60°С
House protection degree IP54
Dimensions 330x140x700 mm
Weight 2,4 kg

Transmitter AG-107 Specifications

Parameter Value
The frequencies of the continuous «Co» or pulse «Pu» signal, Hz ± 0,1% - «kHz»
Load «clips» or «clamp» 512 - «0.5» / 1024 - «1.0» / 8192 - «8.2» / 32768 - «33»
«Antenna» modes 8192 - «8.2» / 32768 - «33»
Operating modes
«Antenna» modes Internal transmitting inductor «In».
External induction transmitting antenna «An».
«Modulation» modes (special form signal) Pulse «Pu» (short-term transmissions of the sine signals). Transmission duration 0,12sec. Transmissions repetition frequency 1Hz.
Dual-frequency «2F» (simultaneous frequency generation 1024Hz, 8192Hz). Amplitudes ratio 4/1 (respectively).
Output parameters under power supply voltage 12…15V
Output current, А
Restricted by the program under manual increment, ≥ 5 – at frequency 512Hz «0.5» / 1024Hz «1.0» / 8192Hz «8.2» / «2F»
3 - at frequency 32768Hz «33»
Maximum output voltage, V
Depending on «modulation», ≥ 48 – in the dual-frequency modulation mode «2F»
60 – in other modes
Maximum output power, W
Restricted by the program, ≥ 30 - In the continuous «Co» at load resistance up to 120Ω In dual-frequency mode «2F» at load resistance up to 77Ω.
60 – in Pu (pulse) mode.
Power supply sources
Operating range of the supply voltages Minimally acceptable voltage for oscillation start-up - 7V.
Maximum allowed voltage for operation – 15V.
Automatic shutdown voltage in the “oscillation” mode < 4,2V.
Battery set 4 LiFePO4 26700 3,2 V elements
External power supply sources (optional) LiFePO4 charger
Operational characteristics
Automatic shutdowns of the device At power supply voltage < 8,8V.
At power supply voltage > 27V.
In case of exceeding of the admissible absorbed current value (the exact figure depends on the actual mode).
In case of short circuit of the output during the adjustment process (actuation of the hardware safety system of the terminal amplifier).
In case of non-compliance of the oscillation mode settings depending on whether the external antenna is installed in the output or not (the switch to the “stop” mode).
In case of “long” (≈ 100sec) downtime in the “stop” mode (if the buttons are not pushed).
Connection options to the utility under examination «Contact» connection with “earth return”.
«Non-contact» connection with application of the internal transmitting antenna «In».
«Non-contact» connection with the use of external induction transmitting antenna «An» (the emission intensity is higher and easier access to the utility in comparison with the internal transmitting antenna «In»).
«Non-contact» connection using the transmitting induction “clamp” (selection of the cable from the bunch is possible).
Structural parameters
Power output amplifier The technology — updated CLASS D Efficiency to 85%.
LED indicators Separate light-emitting diodes indicating parameters and modes.
Digital indicator displaying the modes and parameters values and also showing output parameters of the «MULTIMETER» measurements, e.g.: output voltage (V), load current (А), load power (W) and load resistance (Ω /kΩ).
Overall dimensions of the electronic unit (case), not more than, mm. 216х180х105mm
The weight of the electronic unit, not more than, kg 1,8
The admissible environment temperatures range when in operation - 30°С to +60°С
Ingress protection rating IP65 (when the enclosure-case is shut).

Standard set

Standard set:

  • Receiver АP-019
  • Transmitter АG-107
  • AG-107 charger
  • Power connection cable AG120.02.080
  • Grounding rod
  • Grounding cable
  • Contact magnetic
  • Set carrying bag
  • Receiver bag
  • Operation manual
  • Technical passport

Accessories

Sensor DKI-117

DKI sensor is used with cable locating receiver for location of insulation damage in power cables, gas and heat pipes.

Sensor DODK-117

Searching of cable faults at shorting of its armoring to the ground. Searching of outer insulation defects of metal pipelines (water, gas) at trenchless laying.

Pipe transmitter set MAG-05.X.XX

Set of pipe transmitter MAG-05 used for location and depth measurement of PVC pipelines and drain channels on the depth up to 5m.

Sensor NR-117

Selection of the cable from a bunch.

Clamps CI-110

Identification of the cable, the function "selection the cable from a bunch". Non-contact connection to the pipelines or to the cable. Available in various sizes.

Portable electromagnetic sensor MED-127

MED-127 is used for the selection of the cable from a bunch, for location of internal wiring and cable fault location.

Additional grounding accessory set

Extra grounding wire and rod for better quality of underground utility location.

Type C accumulators with charger

Set of type C rechargeable accumulators and chargers for AP-019 and AG-105.

220V power supply cord

Cord to power your equipment from 220V outlet.

12V power supply cord

Cord to power your equipment from vehicle accumulator.

Download

Download


Datasheet

0.8 MB

If you want to receive price quotation for Cable and pipe locator Success AG-317G, Contact us via email: info@technoac.com or leave a message in "Contact us" section.