Metal and non-metal pipeline locator with water leak detection function Success TPT-522N
The most advanced locating kit combining the functions of three devices: metal cable & pipe locator, water leak detector, non-metal pipe locator. Features AP-027 receiver, powerful transmitter and special impact device for the detection of non-metal pipelines.
Features:
- AP-027 digital location receiver
- 60W AG-144 transmitter
- Acoustic leak detection function
- UM-112 impact device for non-metal pipeline location
Overview
Brief description:
- Two modes of operation: leak detection and route location
- Receiver frequencies: 50 to 60Hz/100 to 120Hz/512Hz 1024Hz/8192Hz/33kHz
- Transmitter frequencies: Hz - 512/ 1024/8192
- Storage of 31 signal level with a graph displayed
- Visual indication of the signal on the display: scale, graphic and spectrum
- Graphic visualization (moving chart) of sequence of measurements, max and min signal levels
- Sound indication
- Choice of bandwidth
- Two-segment indication of frequency spectrum (and “filtered”) signal
- Light weight
- Comfortable to wear for long terms
- LCD display
- Warranty: 1 year
Application:
- Non-metal pipeline location underground
- Water leak detection from metal or non-metal pipelines underground up to 3 m depth
- Water leak detection inside the house
- Detection of cables underground up to 6 m depth
- Detection of any metal pipelines underground up to 6 m depth
- Survey the ground before the ground works (BB mode)
- Tracing of metal utilities at distance up to 5 km
Specifications
Receiver AP-027 Technical specifications
Parameter Tracing Leak detection Type of accepted signal Continious /pulse Continious signal Frequencies of the receiver’s filter Central frequency of quasi- resonant filter 50..60 Hz,100….450 Hz through 50 Hz, 120…540 Hz through 60 Hz, 512 Hz / 1024 Hz / 8192 Hz/ 33kHz Range limitation "below" 0,1 / 0,15 / 0,21 / 0,31 / 0,45 / 0,65 / 0,95 / 1,38 kHz Range limitation "above" 2,00 /1,38 / 0,95 / 0,65 / 0,45 / 0,31 / 0,21 / 0,15 kHz «Broadband», (operating mode) 0,05 to 8,6 kHz 0,09 to 2,20 kHz Gain factor 100 dB Visual indication - Liquid-crystal display-symbols and meaning of the chosen modes and parameters.
- animated (moving) scale of the output signal level
- digital value and animated (moving) scale of the output signal level
- graphic (moving diagram) of the output signal level - frequency content of the output signal level
- digital and graphic display of output signal levels kept in the "memory"
Sound indication Headphones natural broadband or filtered signal Headphones-synthesized sound. Frequency modulation - Built-in emitter - synthesized sound. Frequency modulation - Supply Voltage 4…7 V. - alkaline batteries АА type 1,5 V (4 pcs.). Time of continuous operation not less than 20 hours Ambient temperature -20°С to +50°С Ingress protection rating IP54 Receiver AP-027 dimensions 220 × 102 × 42 (mm) Weight of the electronic unit 0,46 kg Transmitter AG-144 Technical specifications
Parameter Value Frequencies of generated signal, Hz: Frequencies SIN f1/f2/f3, +/- 0,1 % 512/1024/8192 Modes of generation "SIN" "continous"
"SIN" "3 frequencies"
"SIN" "pulse"Output parameters of sinusoidal generation: Max output voltage, V - Internal power supply 220 - with external accumulator 12 V/24 V 330 - power supply from mains 140 Output power, W - Internal power supply 7,5 to 120 - with external accumulator 12 V/24 V 45 to 180 - power supply from mains 18 to 72 Allowed load resistance Any Load matching Auto Power source Integrated accumulator set, mains power supply. Maximum dimensions of the transmitter (in the plastic case), mm 220x160x145 Maximum weight of the transmitter in the plastic case, kg 8,2 Service conditions: Temperatures -30°C +45°C Environmental protection grade IP54 Standard set
Standard set:
- Receiver AP-027
- Acoustic sensor AD-227
- Carrying rod for AD-227
- Extension carrying rod for AD-227
- Contact rods for AD-227
- Electromagnetic sensor EMD-247
- Holder for AP-027
- Transmitter АG-144.1
- Headphones
- Screwdriver
- Inductive antenna IEM-301.3
- Power connection cable AG120.02.080
- External power supply cable AG144.02.070
- Power adapter ESP 120-13,5
- Cable of power adapter YP-22/YC-12
- Power supply cable AG144.02.060
- Grounding rod
- Contact magnetic
- Impact device UM-112
- UM-112 carrying bag
- Set carrying bag
- EMD carrying bag
- Manual and passport
Accessories
Compact acoustic sensor ADM-227
ADM is a mini sensor with magnetic base and extension rod, which is used for pipe diagnostics in hard-to-reach places and survey of valves.
Sensor DKI-117
DKI sensor is used with cable locating receiver for location of insulation damage in power cables, gas and heat pipes.
Sensor DODK-117
Searching of cable faults at shorting of its armoring to the ground. Searching of outer insulation defects of metal pipelines (water, gas) at trenchless laying.
Clamps CI-110
Identification of the cable, the function "selection the cable from a bunch". Non-contact connection to the pipelines or to the cable. Available in various sizes.
Portable electromagnetic sensor MED-127
MED-127 is used for the selection of the cable from a bunch, for location of internal wiring and cable fault location.
Additional grounding accessory set
Extra grounding wire and rod for better quality of underground utility location.
Type C accumulators with charger
Set of type C rechargeable accumulators and chargers for AP-019 and AG-105.
Download
Download
Video
TPT-522N (locating of non-metal pipeline)
This video shows how to locate non-metal pipeline with TPT-522.
If you want to receive price quotation for Metal and non-metal pipeline locator with water leak detection function Success TPT-522N, Contact us via email: info@technoac.com or leave a message in "Contact us" section.