If there are any issues for payments to Russia from your country you can make transfer to our Kazakhstan Partner

Detection and locating, measuring equipment
Water leak detectors, cable and pipe locators

Two-channel data logging thermometer DT-529

Professional, digital, two-channel data logging thermometer DT-529 is used to measure the temperature of liquid, dry, gaseous medium by penetration of the probe in the medium (penetration measurement), contact measurement of the solid surfaces temperature (surface measurement), measurement of the relative humidity of the gaseous non-aggressive medium, atmospheric pressure measurement, air flow speed measurement.

DT-529, depending on the order are in set with hi-prescision probes of different use.

Two-Channel Data Logging Thermometer 529 can be simultaneously mounted with detachable probes of different types connected to the first channel and the resistance thermometer or sensor with unified current output 4..20 mA., connected to the second channel.

DT-529 has the function of automatic reading the type of connected probe.

Features:

  • Accurate measurement of physical quantities with resolution 1; 0,1; 0.01 (can be set in menu);
  • Detachable probe;
  • Simultaneous use of two probes for measurement;
  • Dew point calculation;
  • Saving measurement readings on device’s SD-card;
  • Fast logging of readings at intervals from 1 second to 23 hours 59 minutes 59 seconds;
  • Displaying statistical data of measurement readings, such as max, min readings over the last 90 measurements;
  • Installed batteries or accumulators charge state indication;
  • Setting of the sound signal when the preset limit point of measurement quantity is exceeded;
  • Automatic hibernation after set downtime;
  • Automatic switch off after set downtime;
  • Graphic displaying the measurement readings change over time;
  • Readings in the form of the table or graph saved on SD-card;
  • Protection of batteries from over-discharging;
  • Connection with PC for device setting and saved data checking;
  • External power connection;
  • Automatic saving when switching off the current, averaged, max, min supply voltage, remaining operating time of the device.
  • Humidity, atmospheric pressure, luminosity measurement;
  • Simultaneous measurement of temperature and humidity;
  • 1 year manufacturer's warranty;
  • Powered by standard AA batteries;
  • Graphic color display.

Overview

Purpose:

DT-529 is used for highly precise measurement and logging of the temperature, humidity and dew point temperature by direct contact with the measurement object.

Due to the possibility of changing the probe, accurate measurements can be carried out for almost any media: liquid, dry, solid.

Two measurement channels and a logging function allow you to collect and store on the memory card detailed information about all measurements.

The software supplied with the device allows you to store and check the data on a computer.

Since one of the channels allows you to connect sensors and resistance thermometers with a current from 4 to 20 mA, we recommend the DT-529 as a logger for the joint use of sensors manufactured by TECHNO-AC and sensors of other brands.

Improved devices allow using high-precision probes for:

  • high-precision surface measurements;
  • high-precision air temperature measurements;
  • high-precision atmospheric pressure measurements;
  • work with thermocouples of types K, L, B, R, S;
  • work with sensors of other manufacturers;
  • simultaneous high-precision measurement of temperature and humidity.

Specifications

Parameter Value
Limits of absolute additional instrumental error when measuring temperature caused by changes in atmosphere temperature from normal (from +15 to +25°C) in the range from -20 to +50°C on each 10°C, °C ± 0,5
Limits of absolute additional instrumental error when measuring relative humidity caused by changes in atmosphere temperature from normal (from +15 to +25°C) in the range from -20 to +50°C on each 10°C, % ± 0,5
Limits of absolute additional instrumental error when measuring current signal caused by changes in atmosphere temperature from normal (from +15 to +25°C) in the range from -20 to +50°C on each 10°C, % ±0.5×Δ abs. instr.
DC power supply voltage, V 3
External DC power supply voltage, V 5
The length of the connecting cable between the electronic unit and the probe, m 1*
Weight of the electronic unit, less than, kg 0,2
Overall dimensions of the electronic unit, less than mm 180 × 70 × 27
Average error-free running time, at least, h 10000
Average operational life, at least, years 10

Connectable probes

Connectable probes

Probe type and designation Temperature measuring range,  °C Thermal inertia, s Limits of instrumental error of thermometer in set with probe  
Limits of absolute instrumental error,  °C Limits of relative instrumental error, %  
Penetration probes
PP-150
EPP-150
PP-300
EPP-300
PP-500
EPP-500
EPP-1000
EPP-1500

-40…+200
-40…+200
-40…+300
-40…+300
-40…+600
-40…+600
-40…+600
-40…+600
6 ± 0.5 in the range from -40
to +100 °C
± (0.5 +  (*)) in the range
over +100 °C
Penetration probes
PP
VPP
-40…+200 6 ± 0.5 in the range from -40
to +100 °C
± (0.5 + (*)) in the range
over +100 °C
Air probes
AP-150
AP-500
AP-1000

-40…+200
-40…+600
-40…+600
2 ± 0.5 in the range from -40
to +100 °C
± (0.5 + (*)) in the range
over +100 °C
High-precision air probe HPAP -40…+200 2 ± 0.2 in the range from 0 to +50 °C
± 0.5 in the range from -40 to 0 °C
and from +50 to +100 °C
± (0.5 + (*)) in the range
over +100 °C
Surface probes
SP-150
SP-300
SP-500
SP-1000
BSP-300
BSP-500
-40…+250 10 ± 2 in the range from -40
to +100 °C
± (2 + (*)) in the range
over +100 °C
High-temperature surface probes
HTSP-300
HTSP-500
HTSP-1000
-40…+500 10 ± 2 in the range from -40
to +100 °C
± (2 + (*)) in the range
over +100 °C
High-precision surface probes
HPSP-150
HPSP-300
HPSP-500
-40…+250 10 ± 0.5 in the range from 0 to +50 °C
± 2 in the range from -40 to 0 °C
and +50 to +100 °C
± (2 + (*)) in the range
over +100 °C
Thermocouple probes ****
* TCP (L)
TCP (K)
TCP (B)
TCP (R)
TCP (S)

-100…+800
-100…+1300
+600…+1800
0…+1600
0…+1600
- ± 0,5 ** -

* - resolution (for DT-504 - 1°C; for DT-506, DT-509, DT-511 – 0,1°C).

** - without accounting thermocouple instrumental errors.

*** - error of the built-in air probe is given (without accounting atmosphere).

**** - probe is used to connect with external thermocouples of disposable use with nominal static characteristic of type "B".

***** - probe is used to connect with external thermocouple of specific type (L, K, B, R, or S).

Probe type and designation Temperature measuring range,  °C Relative humidity measuring range, % Thermal inertia, s Limits of instrumental error  
Absolute error, °С Relative error, %  
Humidity and temperature probe
THP-150
THP-500
THP-1000
PTHP-150
-20…+85 0,1…100 5 ± 0,5 ± 3
Flexible temperature & humidity probe FTHP -20...+85 0,1…100 5 ± 0,2 ± 3
Probe type and designation Atmospheric pressure measuring range, mm Hg Temperature measuring range, °C Limits of absolute instrumental error when measuring atmospheric pressure, mm Hg Limits of absolute instrumental error when measuring temperature, °C  
Atmospheric pressure probe APP From 225 to 820 From -20 to +65 ± 2,3 (from 0°С to +65°С
and from 225  to 525)
±1,9 (from 0°С  to +65°С
and from 526 to 820)
±3 (from minus 20°С to 0°С
and from 225 to 820)
± 2

Standard set

Basic set:

  • Two-channel data logging thermometer DT-529 - 1
  • 1.5 V battery, type AA - 2
  • Operation manual (in English) - 1
  • Packaging - 1

Accessories

Accessories:

  • Battery charger
  • Battery AA 1.2 V (2850 mA) - 2 pcs.
  • Case 53141 for a thermometer with 1 probe
  • Case 53142 for a thermometer with 2 probes
  • Case 53143 for a thermometer with 3 probes
  • Case 53134 for thermometer with 4 probes

Calibration

Calibration:

All DT-5 digital thermometers are calibrated and certified as measurement instruments in Russia, Kazakhstan, Belarus.

Contact us if you want to check id DT-5 are certified for your country.

Download

Video

Two channel logging thermometers DT-527, DT-529

Review of the most functional digital thermometers – loggers from TECHNO-AC

If you want to receive price quotation for Two-channel data logging thermometer DT-529, Contact us via email: info@technoac.com or leave a message in "Contact us" section.